The primary function of the compressed air tank is to compensate for pressure fluctuations occurring in the piping network of the compressed air system and to keep the number of switching cycles of the compressor as low as possible. Arranged in the compressed air network, the tank also serves to catch short-term consumption peaks. In addition, it functions as a condensate separator.

The following parameters are included in the dimensioning of the compressed air tank:

  • Total quantity of compressed air supplied
  • Control
  • Compressed air requirement

Scope of supply:

Compressed air reservoir
tank volume [l] 10000
Pressure max. [bar ΓΌ] 16
Surface according to DIN50976 zinc-plated
design vertical / horizontal
set of rules AD2000
attestation for construction and compressed air testing and manufacturer certification

Send us your technical specifications and we will advise you: